TEL +49 23 03.9 61 23-0

Leachate depot

A variety of individual components enable a multitude of system solutions

Our leachate depots are typically built using enamelled steel and operated with a cover. Different materials are available for the cover. In addition to stainless steel, there is also a choice of aluminium, fibreglass (GFK) or tarpaulin. For the concrete floor protection, a variety of systems is available. In addition to leakage-monitored HDPE flooring, we supply single-walled concrete floor protection in various materials. You may choose between HDPE, stainless steel, fibreglass (GFK) or epoxy.

Tank construction is rounded off with a wide range of individual components such as manholes, nozzles, staircases, walkways, insulation and special building components.

Current references

Technology Accessories

1_2_VA_Leichtbaudach

stainless steel lightweight roof

Lightweight roofs are supplied in the stainless steel grades V2A, 1.4301 (AISI 304) and V4A, 1.4404 (AISI 316L). The construction is selected to fit the diameter, static loads and openings. stainless steel lightweight roofs are used, for example, in wastewater tanks, thick sludge depots and leachate depots. Alternative roof systems are also available, such as double-membrane roofs, tarpaulin covers or special solutions.

2_3_Stutzen

Nozzles

For connection of the pipeline, we use nozzles with external loose flange or internal fixed flange. The surfaces in contact with the medium are made of V4A, 1.4404 (AISI 316L).
We also design and install special customer-specific solutions.

2_4_Rohrleitungsbau

Pipeline construction

To ensure an optimal construction process, we offer our customers delivery and installation of piping construction on and in the tank during assembly.
The pipelines are designed according to customer’s desires and specifications.

3_2_Mannloch_epoxy

Manhole / roof hatch

For inspection and maintenance work on the tank or technical installations, we recommend installing a manhole in the lower ring. In accordance with DIN EN ISO 28765, covered tanks must have a manhole DN 800. Manholes can be epoxy-coated or made of V4A stainless steel. In addition to lateral manholes, roofs can be supplied with various hatches. For gas depots, doors are also available. 

5_1_Leiter

Ladder

With a ladder, various operating points on your tank can be easilyreached. The standard material is hot-dip galvanised steel; on request, however, stainless steel or fibreglass (GfK) versions are also available. Alternative access options such as winding staircase, spiral staircases or staircase towers are available. 

5_2_Tankmanteltreppe

Tank jacket staircase

With a tank jacket staircase, various operating points on your tank can be easily reached. The standard material is hot-dip galvanised steel; on request, however, stainless steel versions are also available. We supply winding staircase in widths of 800 mm and 1,000 mm. Alternative access options such as ladders, spiral staircases or staircase towers are available. 

5.3_Spindeltreppe2

Spiral staircase

With a spiral staircase, various operating points on your tank can be easily reached. The standard material is hot-dip galvanised steel; on request, however, stainless steel versions are also available. Alternative access options such as ladders, winding staircase or staircase towers are available. 

6_1_Podest

Platform

We offer walkways in various designs. Polygonal walkways on the jacket or straight/sloping roof walkways are designed in accordance with EN 14122. We use standard widths of 800 mm or 1,000 mm. Walkways and platforms have gratings according to R12. They are connected to the tank wall via the substructure.

7_1_Mantel--und_Dachisolierung

Jacket and roof insulation

We supply jacket and roof insulation in different insulation thicknesses and with steel or aluminium trapezoidal sheet metal. The roofs are clad with smooth sheet metal. Trapezoidal sheet manufacturers offer a wide choice of standard colours. Special colours can be achieved through powder coating, for example. The manhole is fitted with a removable manhole cap as standard.

8_1_PEHD_Boden

HDPE flooring

Concrete floor protection can be provided in various construction types. In the area of leachates, HDPE has become the standard. For low pressure gas depots, we use welded stainless steel flooring. Other alternatives, such as bolted stainless steel flooring or coatings, are also available.